Specifications
Environmental specifications
Specification Value
Temperature range
1
Operating 10°C to 35°C (50°F to 95°F)
Non-operating -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)
2
Operating 10% to 90% @ 28°C (824°F)
Non-operating 5% to 95% @ 387°C (1017°F )
Altitude
3
Operating 3050 m (10000 ft)
Non-operating 9144 m (30000 ft)
1
The following temperature conditions and limitations apply:
All temperature ratings shown are for sea level.
An altitude derating of 1°C per 3048 m (18°F per 1000 ft) up to 3048 m (10000 ft) applies.
No direct sunlight is allowed.
The maximum permissible rate of change is 10°C/hr (18°F/hr).
The type and number of options installed might reduce the upper temperature and humidity limits.
Operating with fan fault or above 30°C (86°F) might reduce system performance.
2
Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F).
3
Maximum storage altitude corresponds to a minimum pressure o 70 kPa (101 psia).
Compute module physical specifications
The following details physical specifications for the HPE Synergy 480 Gen10 compute module.
Specification
Value
Height 6360 mm (250 in)
Depth 60650 mm (2388 in)
Width 21400 mm (843 in)
Weight (maximum) 816 kg (1800 lb)
Weight (minimum) 657 kg (1450 lb)
Specifications 114