NIST SP800-88 Guidelines for Media Sanitization (Rev 1, Dec 2014) is available for download from the NIST website (http://
nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-88r1.pdf).
NVDIMM relocation guidelines
Requirements for relocating NVDIMMs or a set of NVDIMMs when the data must be preserved
The destination graphics expansion module hardware must match the original graphics expansion module hardware
configuration.
All System Utilities settings in the destination graphics expansion module must match the original System Utilities settings
in the original graphics expansion module.
If NVDIMM-Ns are used with NVDIMM Interleaving ON mode in the original graphics expansion module, do the following:
Install the NVDIMMs in the same DIMM slots in the destination graphics expansion module.
Install the entire NVDIMM set (all the NVDIMM-Ns on the processor) on the destination graphics expansion module.
This guideline would apply when replacing a system board due to system failure.
If any of the requirements cannot be met during NVDIMM relocation, do the following:
Manually back up the NVDIMM-N data before relocating NVDIMM-Ns to another graphics expansion module.
Relocate the NVDIMM-Ns to another graphics expansion module.
Sanitize all NVDIMM-Ns on the new graphics expansion module before using them.
Requirements for relocating NVDIMMs or a set of NVDIMMs when the data does not have to be preserved
If data on the NVDIMM-N or set of NVDIMM-Ns does not have to be preserved, then
Move the NVDIMM-Ns to the new location and sanitize all NVDIMM-Ns after installing them to the new location. For more
information, see NVDIMM sanitization.
Observe all DIMM and NVDIMM population guidelines. For more information, see
DIMM and NVDIMM population
information.
Observe the process for removing an NVDIMM.
Observe the process for installing an NVDIMM.
Review and configure the system settings for NVDIMMs. For more information, see
Configuring the graphics expansion
module for NVDIMMs .
Recovering restored data from an NVDIMM-N DRAM
CAUTION: Do not remove an NVDIMM when any LEDs on any NVDIMM in the system are illuminated. Removing an
NVDIMM when an LED is illuminated might cause a loss of data.
CAUTION: Electrostatic discharge can damage electronic components. Be sure you are properly grounded before
beginning this procedure.
Removal and replacement procedures 62