Item Description Status
4 Mezzanine NIC status LED
Solid green= Link on any Mezzanine NIC
Flashing green= Activity on any Mezzanine NIC
O = No link or activity on any Mezzanine NIC
5 Power On/Standby button
and system power LED
Solid green = System on
Flashing green (1 Hz/cycle per sec) = Performing power on sequence
Solid amber = System in standby
O = No power present
NOTE: If all other LEDs are o, no compute module power is present
(facility power is not present, power cord is not attached, power
supplies are not installed, power supply failure has occurred, or the
power button cable is disconnected). If the health LED is flashing green
while the system power LED is o, the Power On/Standby button
service is initializing or an iLO reboot is in progress.
Drive numbering
Depending on the configuration, this graphics expansion module can support hard drives, SSDs, NVMe drives, and uFF drives
(supported in dual SFF flash adapters) in the drive bays. Depending on the device installed, the bay number might be
dierent.
Item
Hard drive/SSD bay
numbering
uFF drive bay numbering NVMe drive bay numbering
1 1 1 and 101 1
2 2 2 and 102 2
Component identification 97