10. TECHNICAL SPECIFICATIONS
10.1. TECHNICAL CHARACTERISTICS
Accuracy is indicated as ±[%reading + (num. dgt*resolution)] at 23°C±5°C, <80%RH
ELECTRICAL SAFETY
DMM – DC Voltage
Range [V] Resolution [V] Accuracy
3 1500
1
(1.0rdg + 2dgt)
DMM – AC TRMS Voltage
Range [V] Resolution [V] Accuracy
3 1000
1
(1.0rdg + 3dgt)
Frequency range: 42.5 ÷ 69Hz ; Voltages zeroed for measured value <3V
M - Insulation resistance R(+), R(-), Rp – DUAL Mode
Test voltage DC [V]
Range [M
] Resolution [M]
Accuracy (*)
250, 500, 1000, 1500
0.1
0.99
0.01
(5.0
rdg + 5dgt) 1.0 19.9
0.1
20 100
1
(*) Accuracy declared for VPN240V, Rfault10;. Accuracy of Rp and R(+) notdeclared if R(+)0.2M and R(-)<0.2M
,
Accuracy of Rp and R(-) not declared if R(+) < 0.2M and R(-) 0.2M.
Open circuit voltage <1.25 x rated test voltage
Short-circuit current <15mA (peak) for each test voltage
Rated test current > 1mA on R = 1k x Vnom (with VPN, VPE, VNE= 0)
Insulation resistance (M) – TIMER mode
Test voltage DC [V]
Range [M
] Resolution [M]
Accuracy
250, 500, 1000, 1500
0.01
9.99
0.01
(5.0
rdg + 5dgt)
10.0 99.9
0.1
Open circuit voltage <1.25 x rated test voltage
Short-circuit current < 15mA (peak) for each test voltage
Rated test current > 1mA on R = 1k x Vnom (with VPN, VPE, VNE= 0)
Selectable Timer: 3s ÷ 999s
Continuity of protective conductors (RPE)
Range [
] Resolution []
Accuracy
0.00 9.99
0.01
(2.0
rdg + 2dgt) 10.0 99.9
0.1
100 1999
1
Test current: >200mA DC up to 5 (cables included), resolution 1mA, accuracy (5.0%reading + 5digits)
Open-circuit voltage 4 < V
0
< 10V
GFL– Ground Fault Locator
Test voltage DC
[V]
Range [M
]
Resolution
[M
]
Accuracy Rp(*)
Accuracy
Position
250, 500, 1000,
1500
0.1
0.99
0.01
(5.0
rdg + 5dgt)
1 module
1.0 19.9
0.1
20 100
1
(*) Accuracy declared for VPN240V, Rfault10;. Accuracy of Rp and R(+) notdeclared if R(+)0.2M and R(-)<0.2M
,
Accuracy of Rp and R(-) not declared if R(+) < 0.2M and R(-) 0.2M.
Open circuit voltage <1.25 x rated test voltage
Short-circuit current <15mA (peak) for each test voltage
Rated test current > 1mA on R = 1k x Vnom (with VPN, VPE, VNE= 0)
Measuring limit: 0.05M, 0.1M, 0.23M, Number of modules: 4 ÷ 35
The GFL function provides correct results with the following conditions:
Test carried out with Vtest Vnom on a single string disconnected from inverter, from overvoltage protections and earth
connections.
Test carried out upstream of possible blocking diodes
Single fault of low insulation located at any position in the string
Insulation resistance of the single fault <0.23M
Environmental conditions similar to those in which the fault occurred