6.8. LIST OF DISPLAY MESSAGES
MESSAGE DESCRIPTION
Function not available The selected function/characteristic is not available
Data not saved The instrument was not able to save the data
Wron
g
date Set a correct s
y
stem date
Database full The number of modules added to the internal DB is > 30
Module alread
y
added The name of the module has alread
y
been added to the DB
Memor
y
full Instrument memor
y
full upon pressin
g
the GO ke
y
Error: Vmpp >= Voc Check module settin
g
s inside DB
Error: Impp >= Isc Check module settin
g
s inside DB
Error: Vmpp * Impp >= Pmax Check module settin
g
s inside DB
Error: Alpha too hi
g
h Check module settin
g
s inside DB
Error: Beta too hi
g
h Check module settin
g
s inside DB
Error: Toll too hi
g
h Check module settin
g
s inside DB
Download error Contact service department
Error while savin
g
Problems when accessin
g
the memor
y
Remote unit undetected The instrument does not detect an
y
remote unit SOLAR03
Unable to perform anal
y
sis Problems with the data downloaded from SOLAR03. Check settin
g
s
Data unavailable Generic error. Repeat the test.
Ne
g
ative volta
g
e Check the polarit
y
of the instruments input terminals
Low volta
g
e Check the volta
g
e between input terminals P and N
Vin > 1500 Volta
g
e between input terminals > 1500V
Wron
g
no. of modules. Continue? Set no. of modules inconsistent with measured Voc
Temp. Ref. cell exceedin
g
limits Temperature measured b
y
reference cell too hi
g
h
Cell temp. undetected
(
ENTER/ESC
)
Measurement not carried out on module cell
Low batter
y
Low batter
y
char
g
e. Insert new batteries.
Please wait for coolin
g
Instrument overheated. Wait before resumin
g
the test.
Irradiance too low Irradiance value lower than the minimum threshold set
NTC Error Internal NTC efficienc
y
j
eopardized. Contact service departmen
t
Current < Lim
Current measured between P and N lower than the minimum
detectable value
EEPROM Error: contact service Internal instrument error
FRAM Error: contact service Internal instrument error
RTC Error: contact service Internal instrument error
RADIO Error: contact service Internal instrument error
FLASH Error: contact service Internal instrument error
IO EXP Error: contact service Internal instrument error
Volta
g
e > limit Volta
g
e between terminals E and C > 10V
Label already assigned
Change the numeric reference of the marker associated with the
measure
Isc current < Lim
Isc current lower than the minimum detectable value. Contact service
departmen
t
Warnin
g
: internal short-circui
t
Contact service department
Warnin
g
: blown fuse Contact service department
Reset calibration. Press ENTER.
Resistance value of input cables > 2
Calibration not OK Calibrated resistance value > measured resistance
Error: Isc offset measurement Internal instrument error
Rcal > measured R Calibrated resistance value > measured resistance
Warnin
g
: AC volta
g
e at P-N terminals Presence of
A
C input volta
g
e
Wait for condenser dischar
g
e Wait for dischar
g
e of tested ob
j
ect after insulation