EasyManuals Logo

Huawei DBS3900 User Manual

Huawei DBS3900
556 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #493 background imageLoading...
Page #493 background image
Figure 13-50 Cable connections in the AC power supply scenario
CAUTION
l You may need to prepare cables according to actual cable routes during the cable installations.
l Attach engineering labels to both ends of the cable after each cable is installed.
l When routing the power cable and PGND cable on the bottom of the IMB03, ensure that the
holes for heat dissipation are not covered.
l When the IMB03 is installed on the wall, the distance between the E1/T1 cable and the GPS
clock signal cable must be not less than 10 mm.Figure 13-51 shows cable routes.
DBS3900 (Ver.B)
Installation Guide 13 Indoor Scenario (BBU Installed in an IMB03)
Issue 06 (2011-09-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
480

Table of Contents

Other manuals for Huawei DBS3900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei DBS3900 and is the answer not in the manual?

Huawei DBS3900 Specifications