Figure 4-5 Battery control parameter setting
Parameter Description Value Range
Working mode Set this parameter to the maximum
self-consumption mode.
● Maximum self-
consumption
● TOU (time-of-use)
● Fully fed to grid
Maximum charge
power (kW)
Retain this parameter to the maximum
charge power. Additional conguration
is not required.If only one battery
expansion module is congured, the
maximum charge power is 2.5 kW.
[0, Maximum charge power]
Maximum discharge
power (kW)
Retain this parameter to the maximum
discharge power. Additional
conguration is not required.If only one
battery expansion module is congured,
the maximum charge power is 2.5 kW.
[0, Maximum discharge
power]
End-of-charge SOC (%) Set the charge cuto capacity. 90%–100%
LUNA2000-(5-30)-S0
User Manual 4 Application Scenarios and Settings
Issue 15 (2024-01-12) Copyright © Huawei Digital Power Technologies Co., Ltd. 43