Parameter Description Value Range
End-of-charge SOC
(%)
Set the charge cuto capacity. 90%–100%
End-of-discharge
SOC (%)
Set the discharge cuto
capacity.
0%–20%
Charge from grid If Charge from grid function is
disabled by default, comply
with the grid charge
requirements stipulated in local
laws and regulations when this
function is enabled.
● Disable
● Enable
Grid charge cuto
SOC
Set the grid charge cuto SOC. [20%, 100%]
If no PV modules are installed or the system has not detected sunlight for at least 24 hours,
the minimum end of discharge SOC is 15%.
7.3.3 Querying the Battery Status
Scenario 1: Single Inverter or Cascaded System Based on Smart Dongle
Networking
Log in to the FusionSolar app as installer, connect to the inverter, and tap Device
monitoring on the home screen to check the running status, battery level, power,
and charging and discharging status of the ESS. If an alarm is generated, see 7.3
''Troubleshooting''.