Cause Analysi
s:
The fact of cause phenomenon is
that computers and some other manufactory devices automatically adopt daylight saving time and MA5600T
d
hand for that feature.
Handling Proces
s:
1. Chekced that NTP server works properly
2. Debug NTP service on MA5600T
MA5600T(config)# debugging ntp-service all
After analyzing debug messages, the problem was cleared:
Our device didn't automatically adopted DST, so that to solve the problem just need to add the following strin
g
MA5600T(config)#time dst start 3 last sun 03:00:00 end 10 last sun 04:00:00
3.Problem solved
2.9 Smart MX 5600T PPP use cannot get IP cause by BAS malfunction
Title:
Smart MX 5600T PPP use cannot get IP cause by BAS malfunction
ID: SE0000333018
Information
Type :
Troubleshooting Cases Quality Level:
C
Update Time: 2008-06-24 11:55:34
Views: 21
Author: 88583Eduardo Rodriguez
Product Family:
Broadband Access
Product:
MA5600T MSAN
Fault Type:
Routing Protocol
Keywords: PPPoE BAS
Permission
Level:
04Common Users Permission
Phenomenon De
scription:
Smart MX 5600T release: MA5600V800R003C02B108SP01.
The DSLAM's ppp subscribers on VLAN 2490 can not get IP.
Network diagram: ISP Subscribers -- Huawei DSLAM -- External BRAS.
Alarm Informatio
n:
Null
Cause Analysi
s:
1.Check the vlan traffic on the DSLAM. Command:
#display statistics vlan 2490.
2.After analyzed the traffic, if we have got upstream traffic and we don't have downstream traffic.
3.Check the connectivity to BRAS: Command:
#display mac-address vlan 2490.
We should have an MAC-entry on uplink port from BRAS machine.
Example:
eth 0013-c308-fa60 dynamic 0 /19/0 - 2543 << Vlan and MAC associated on uplink port.
4.If we don't have this entry. We can locate this problem is came from BRAS/Datacom department.
Handling Proces
s:
After the right test on DSLAM. The ISP found the BRAS problem. They reset its interface to our DSLAM and t
h
Suggestions and
Summary:
Null