NGN Cases Chapter 5 UA5000 Narrow-band Service
Confidential Information of Huawei. No Spreading without Permission
78
Suggestions and
Summary:
According to H.248, the long timer prevails when the long timer conflicts with the short timer.
This must be taken into consideration when a logical digitmap is edited.
5.6 Activation Failure of the IUA Link on the UA5000 Because the Corresponding Port on
the SoftSwitch Firewall Is Not Enabled
Title:
Activation Failure of the IUA Link on the UA5000 Because the Corresponding Port on the
SoftSwitch Firewall Is Not Enabled
ID: SE0000394390
Update Time: 2009-06-24 14:10:59
Views: 2
Author: l92907
Product Family: Integrated Access Product: UA5000
Fault Type: Narrow-band Voice Service
Keywords: ISDN, link, activation
Permission
Level:
04Common Users Permission
Phenomenon De
scription:
In an office, the UA5000 ISDN service is configured. After the IUA link set and IUA link are
configured, the IUA link cannot be activated. The queried status is down.
Alarm Informati
on:
Null
Cause Analysi
s:
1. The UA5000 MG interface is abnormal.
2. The data on the UA5000 is inconsistent with the data on the SoftSwitch.
3. The network device screen the port of the IUA link.
Handling Proce
ss:
1. Check the status of the UA5000 MG interface. It is found that the interface is normal.
2. Check data on both the UA5000 and the SoftSwitch. It is found that the data is consistent. In
addition, the port number and IP address correspond with each other.
3. The network device may screen the port of the IUA link. Check the configurations of the
UA5000, SoftSwitch, and intermediate network device. It is found that the local port for the
UA5000 IUA link is not enabled on the SoftSwitch firewall. Modify the configuration of the
firewall. Then the problem is solved.
Suggestions and
Summary:
The IUA link and the MG interface use different ports to register with the SoftSwitch. The
bearer network and the SoftSwitch should enable the port of the IUA link.
5.7 Busy Tone Upon Off-hook Due to the Abnormal Maximum Leak Rate After the UA5000
Is Upgraded
Title:
Busy Tone Upon Off-hook Due to the Abnormal Maximum Leak Rate After the UA5000 Is
Upgraded
ID: SE0000394174
Update Time: 2009-06-24 14:11:44
Views: 6
Author: h93689
Product Family: Integrated Access Product: UA5000
Fault Type: Narrow-band Voice Service

Table of Contents

Related product manuals