cluster enable
 ntdp enable
 ntdp hop 5
 ntdp timer 10
 ndp enable
#
interface Vlanif10
#
interface Ethernet0/0/1
 port link-type trunk
 port trunk allow-pass vlan 10
 ntdp enable
 ndp enable
#
cluster
 administrator-address 0001-0001-0001 name HUAWEI
#
 mngvlanid 10
 ip route-static 2.0.0.0 255.0.0.0 10.0.0.1
#
return
l Configuration file of Member-3.
#
 sysname Member-3
#
 vlan batch 10
#
cluster enable
 ntdp enable
 ntdp hop 5
 ntdp timer 10
 ndp enable
#
interface Vlanif10
#
interface Ethernet0/0/1
 port link-type trunk
 port trunk allow-pass vlan 10
 ntdp enable
 ndp enable
#
cluster
 administrator-address 0001-0001-0001 name HUAWEI
#
 mngvlanid 10
 ip route-static 2.0.0.0 255.0.0.0 10.0.0.1
#
return
3.6.4 Example for Configuring Devices in the HGMP Cluster to
Access the Outside SNMP Host (in NAT Mode)
Networking Requirements
As shown in Figure 3-6, all the Layer 2 switches belong to the same cluster. Administrator-1 is
the administrator switch of the cluster and other switches are member switches. The member ID
of Member-2 is 2 and the member ID of Member-3 is 3.
When Member-1, Member-2, and Member-3 are required to send packets to the SNMP host, a
connection can be set up between the SNMP host out of the cluster and member switches in
NAT or non-NAT mode.
Quidway S2700 Series Ethernet Switches
Configuration Guide - Network Management 3 HGMP Configuration
Issue 01 (2011-07-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
138