Page #306 background image
No. Data
1 Administrator name and test name
2 Round-trip transmission delay threshold
6.16.2 Configuring Round-Trip Delay Thresholds
This part describes how to set a round-trip transmission delay threshold. When the transmission
duration exceeds the threshold, a trap message is sent to the Network Management System
(NMS).
Context
Do as follows on the switch to perform the NQA test:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the NQA instance view is displayed.
Step 3 Run:
test-type test-type
The test type is configured.
Step 4 Run:
destination-address ipv4 ip-address
The destination IP address is configured.
Step 5 (Optional)Run:
destination-port port-number
The destination port number is configured.
Step 6 Run:
threshold rtd rtd-value
The round-trip transmission delay threshold is configured.
Step 7 Run:
send-trap rtd
The trap function is enabled.
----End
Quidway S2700 Series Ethernet Switches
Configuration Guide - Network Management 6 NQA Configuration
Issue 01 (2011-07-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
296

Table of Contents

Other manuals for Huawei Quidway S2700 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S2700 series and is the answer not in the manual?

Huawei Quidway S2700 series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S2700 series
CategorySwitch
LanguageEnglish

Related product manuals