The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
test-type { jitter }
The test type is configured.
Step 4 Run:
destination-address ipv4 ip-address
The destination IP address is configured.
Step 5 (Optional)Run:
destination-port port-number
The destination port number is configured.
Step 6 Run:
send-trap testfailure
Sending trap messages when tests fail is enabled.
By default, the trap function is disabled.
Step 7 Run:
test-failtimes times
The number of test failures that trigger sending a trap message is configured.
By default, a trap message is sent for each test failure.
----End
6.17.3 Sending Trap Messages When Probes Failed
A trap message is sent to the NMS when the NQA test fails.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
test-type { jitter }
The test type is configured.
Step 4 Run:
destination-address ipv4 ip-address
Quidway S2700 Series Ethernet Switches