Context
Do as follows on the NQA server (TCP server):
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa-server tcpconnect ip-address port-number
The TCP monitoring service is configured.
NOTE
Note that the IP address and port number monitored by the server should be consistent with those configured
on the client.
----End
6.12.3 Configuring the TCP Client
This part describes how to set TCP test parameters.
Context
Do as follows on the NQA client (TCP client):
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
test-type tcp
The test type is set to TCP.
Step 4 Run:
destination-address ipv4 ip-address
The destination IP address is configured.
Step 5 To configure the destination port number, run the destination-port port-numbercommand.
Step 6 (Optional) Perform the following as required to configure other parameters for the TCP test ( For
detailed parameter configurations, see the chapter Configuring Universal NQA Test
Parameters ):