NOTICE
l When cables from the PSTN and LINE ports are routed to an outdoor environment, the
MDF must be installed with a protective unit.
l When cables from the LINE port are routed to the user side, the MDF must be installed
with a protective unit.
l The PSTN port must be connected to an MDF with a protective unit or a POTS device.
Otherwise, when the LINE port is struck by lightning, energy inside the SPL board or unit
fluctuates and overlaps, which may damage the LINE port.
Pin Assignments
The pin assignments of xDSL, LINE, and PSTN ports on the H801VSPLC board are the
same. Table 3-223 describes the pin assignments of the xDSL0 port, and Table 3-224
describes the pin assignments of the xDSL1 port.
Table 3-223 Pin assignments of the xDSL0 port
Pin
Signa
l
Pin Signa
l
Port Pin Signa
l
Pin Signa
l
1 7 17 15
64
48
32
16
1
17
33
49
33 23 49 31
2 18 34 50
3 6 19 14 35 22 51 30
4 20 36 52
5 5 21 13 37 21 53 29
6 22 38 54
7 4 23 12 39 20 55 28
8 24 40 56
9 3 25 11 41 19 57 27
10 26 42 58
11 2 27 10 43 18 59 26
12 28 44 60
13 1 29 9 45 17 61 25
14 30 46 62
15 0 31 8 47 16 63 24
16 32 48 64
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Hardware Description
3 Board
Issue 24 (2018-07-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
832

Table of Contents

Other manuals for Huawei SmartAX MA5600T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5600T and is the answer not in the manual?

Huawei SmartAX MA5600T Specifications

General IconGeneral
BrandHuawei
ModelSmartAX MA5600T
CategoryControl Unit
LanguageEnglish

Related product manuals