Specications Inverter Built-
in WiFi
WLAN-FE Smart
Dongle
4G Smart Dongle
Bandwidth 20 MHz/40 MHz
(optional)
20 MHz/40 MHz
(optional)
LTE features:
Supports a maximum of 3GPP R8 non-
CA Cat 4 FDD and TDD.
Supports 1.4 MHz/3 MHz/5 MHz/10
MHz/15 MHz/20 MHz RF bandwidth.
Supports MIMO in the downlink.
LTE-FDD: maximum downlink rate of
150 Mbit/s and maximum uplink rate
of 50 Mbit/s
LTE-TDD: maximum downlink rate of
130 Mbit/s and maximum uplink rate
of 30 Mbit/s
UMTS features:
Supports 3GPP R7 HSDPA+, HSDPA,
HSUPA, and WCDMA.
Supports QPSK and 16QAM
modulation.
HSDPA+: maximum downlink rate of
21 Mbit/s
HSUPA: maximum uplink rate of 5.76
Mbit/s
WCDMA: maximum downlink rate of
384 kbit/s and maximum uplink rate
of 384 kbit/s
GSM features:
GPRS:
Supports GPRS multislot class 12.
Coding schemes: CS-1, CS-2, CS-3, and
CS-4
Maximum downlink rate: 85.6 kbit/s;
maximum uplink rate: 85.6 kbit/s
EDGE:
Supports EDGE multislot class 12.
Supports GMSK and 8-PSK modulation
and coding schemes.
Downlink coding format: MCS 1–9
Uplink coding format: MCS 1–9
Maximum downlink rate: 236.8 kbit/s;
maximum uplink rate: 236.8 kbit/s
SUN2000-(20KTL, 29.9KTL, 30KTL, 36KTL, 40KTL)-
M3
User Manual 10 Technical Specications
Issue 11 (2023-01-10) Copyright © Huawei Technologies Co., Ltd. 93

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-M3 and is the answer not in the manual?

Huawei SUN2000-M3 Specifications

General IconGeneral
TypeString Inverter
Rated AC Grid Frequency50 Hz / 60 Hz
DC Connection TypeMC4
Protection DegreeIP65
Cooling MethodNatural convection
CategoryInverter
Adjustable Power Factor Range0.8 leading - 0.8 lagging
Total Harmonic Distortion (THD)≤ 3 %
Operating Temperature Range-25°C to 60°C
CommunicationRS485
Efficiency98%
Protection LevelDC reverse polarity protection, AC overcurrent protection, AC short-circuit protection, Overvoltage protection, Insulation monitoring, Residual current monitoring unit, Arc fault detection