The Flow-Clik monitors for a high flow condition, shutting
down the system or individual zone when overflow occurs.
Once the system has been shut off due to a high flow
condition, the Flow-Clik turns the system back on automati-
cally after a pre-selected amount of time has passed. By
waiting out a selected amount of time allows for the system
to resume watering areas that may not be affected by the
āproblem.ā
The Interface Box offers nine pre-
selected off times from 5 to 60
minutes that are programmable by a
single rotary switch. To set the Inter-
rupt Period, turn the dial on the right
of the Interface Box to the desired
period of time you would like the
Flow-Clik to keep the system off after
a high flow condition has occurred
before continuing to irrigate.
Example: A system that is mostly spray zones set for 10
minute run times could select a delay of 10 minutes so the
system is only off during the operation if a single zone.
A manual restart feature is also provided. If the dial is set
to the Restart Manually position, and an over flow condition
is detected by the Flow-Clik, irrigation will not resume until
the system has been manually reset.
To manually restart the system after an overflow condi-
tion has occurred:
Press the Restart System button once on the Interface Box.
The System Status indicator light will change from red to
green or flashing green (if flow is occurring).
Sensor Bypass
The Sensor Bypass setting allows the user to manually
override the Flow-Clik sensor. This is helpful during situ-
ations that require the system to operate at higher than
ālearnedā flow rates (i.e. system winterization, running a
hose bib, or operating multiple valves).