22
TROUBLESHOOTING GUIDE ..........................................................................
PROBLEM CAUSE SOLUTION
System Status Indicator
light is off
No AC power to the Flow-Clik
Interface Box
A) Check that the Interface Box power leads (yellow wires) are
attached to the 24 VAC terminals on the controller.
B) Verify that the power to the controller is on.
System Status Indicator
light is ashing red
Irrigation system is in an overow
condition
Normal operation during an overow condition. The Flow-Clik has
identied overow condition and is waiting the pre-set startup
delay period before shutting the system off.
System Status Indicator is
steady red
Irrigation system is in an overow
condition
Normal operation during an overow condition.
A) The Flow-Clik has identied an overow condition and is
waiting the predetermined amount of time set as the Interrupt
Period before restarting the irrigation cycle.
B) The Interrupt Period setting is in the Manual Restart position
requiring that the Flow-Clik be reset before irrigation can resume.
Press the Restart System button to reactivate the Flow-Clik.