EasyManua.ls Logo

Hunter FLOW-CLIK - Setting the Startup Delay

Hunter FLOW-CLIK
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
21
The high velocities that are common
during initial activation of an irriga-
tion cycle could cause the Flow-Clik
to sense a high flow situation (pri-
marily due to air trapped within the
system) and subsequently shut down
the irrigation system at the begin-
ning of every cycle. The Flow-Clik
addresses the problem by providing a
programmable Startup Delay to allow the system to stabilize
prior to the Flow-Clik monitoring for high flow conditions.
To program the Startup Delay, turn the dial on the left side
of the Interface Box to one of the eight preset delay posi-
tions from 20 seconds to 300 seconds.
Note: The 0 second delay position is used
for calibration of the Flow-Clik during initial
installation only.
Note: The startup delay required may vary
between zones. Select the largest start up
delay required for all zones.
SETTING THE STARTUP DELAY....................................................................