Flow-Clik will not shut the
irrigation system off
No power to Flow-Clik
Faulty wire connections from the
Flow-Clik sensor to the Interface Box
System has not reached an overow
condition
System is in the Startup Delay mode
Check System Status Indicator light is on (if light is off, see
above).
Check Flow-Clik sensor wires (red and black wires) are properly
connected.
A) Normal operation.
B) System is not balanced. Too much variation between ow rates
of the zones may prevent the Flow-Clik from sensing an overow
condition on the lower ow zone(s). Flow-Clik can only sense
ows above the system maximum.
Wait for start up delay period to end.
Flow-Clik continually shuts
off a zone with no known
problems
Flow-Clik is improperly calibrated
High uctuations in system pressure
Reset the Flow-Clik to the highest ow zone.
It is recommended that the Flow-Clik be set at the time of day
that the irrigation system will be run. Note: If too much pressure
uctuation occurs, it may be necessary to add pressure regulation
to the system.