VM Series Maintenance and Safety Manual 704-0212-209 Machine Maintenance 3- 19
Change the Liquid Temperature Setting
Press and hold the Set function key. The display shows 888 initially, then the Liquid
Temperature Setting appears. To change this value, press Set again. Then press the Plus
(+) or Minus (-) function key.
Hurco recommends setting the value for the
Differential Liquid Temperature Setting parameter to -2°
C.
The default value is +10° C.
To save changes, press and hold the Set function key after making a
change. The spindle chiller reverts to the temperature display mode
if no further instructions are given within 30 seconds.