6.2.2.7 Hysteresis Essence Injection (G6)
With this parameter, you set the cabin temperature at which essence
delivery is enabled. The essence system is released to operate at a
temperature value of Steam Bath °C Set Value (G2) - Hysteresis
Essence Injection (G6).
Example: G2 is set to 45 °C and G6 is set to 25 K. Essence delivery
release occurs at 20 °C.
Values between 0 and 25 K are programmable. The preset value is 25
K.
6.2.2.8 Hysteresis °C Max (G7)
With this setting, you set the maximum cabin temperature at which the
steam generator must be shut off as a safety precaution.
Example: G2 is set to 45 °C and G7 is set to 10 K. The steam genera-
tor shuts off at 55 °C.
Values between 0 and 25 K are possible. The preset value is 10 K.
6.2.2.9 Fan Run-On Time (G8)
With this parameter, you determine if and how long the fan should run
after the safety interlock opens.
Using Fan Run-On Time (G8) when Exhaust Fan (D1) is set to “Auto-
matic”, the fan is continuously enabled for the Run-On Time Delay (G8)
by the opening of the safety interlock.
Values between 0 and 999 minutes are programmable. The preset
value is 0 minutes.
6.2.2.10 Power Retention (G9)
With this parameter, you determine whether the steam generator will
shut off when the desired steam bath temperature is reached, or
whether it will switch over to an adjustable power retention of 0-50%.
The power retention continues operating until the temperature falls
below the value Steam Bath °C Set Value (G2). If too high a power
retention causes the Steam Bath °C Set Value + Hysteresis Max. °C
(G7) to be exceeded, the control deactivates with the Fault °C Max.