EasyManua.ls Logo

HygroMatik Basic-DS - Page 57

HygroMatik Basic-DS
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SPA
Page 57
Jumper I
The standard setting for this jumper is open.
This jumper may not be jumpered or only jumpered after consultation
with HygroMatik.
Jumper J
The standard setting for this jumper is open.
This jumper may not be jumpered or only jumpered after consultation
with HygroMatik.
Jumper K
The standard setting for this jumper is open.
This jumper may not be jumpered or only jumpered after consultation
with HygroMatik.
Jumper L
The standard setting for this jumper is open.
This jumper may not be jumpered or only jumpered after consultation
with HygroMatik.
Jumper E and J inverted
After the preprogrammed number of operations of the main contactor
(K1) the HygroMatik control provides the message "Maintenance K1".
During this, the green LED blinks rapidly. By appropriately setting of
the jumpers, this message can be reset. Therefore please turn off the
unit and identify the status (open or closed) of the jumpers E and J. By
inserting or removing the jumpers create inverted status of jumpers.
Turn on the unit for about 5 seconds. Then turn off the device and
restore the old status of the jumpers. This resets the message.
Please note
Please note
Please note
Please note

Table of Contents

Related product manuals