Compliance Information  EMC-1
7/10
ELECTROMAGNETIC COMPATIBILITY EMC 
Introduction
Hypertherm’s CE-marked equipment is built in compliance 
with standard EN60974-10. The equipment should be 
installed and used in accordance with the information 
below to achieve electromagnetic compatibility.
The limits required by EN60974-10 may not be adequate 
to completely eliminate interference when the affected 
equipment is in close proximity or has a high degree of 
sensitivity. In such cases it may be necessary to use other 
measures to further reduce interference.
This cutting equipment is designed for use only in an 
industrial environment.
Installation and use
The user is responsible for installing and using the plasma 
equipment according to the manufacturer’s instructions.
If electromagnetic disturbances are detected then it shall 
be the responsibility of the user to resolve the situation 
with the technical assistance of the manufacturer. In some 
cases this remedial action may be as simple as earthing 
the cutting circuit, see Earthing of the workpiece. In other 
cases, it could involve constructing an electromagnetic 
screen enclosing the power source and the work 
complete with associated input filters. In all cases, 
electromagnetic disturbances must be reduced to the 
point where they are no longer troublesome.
Assessment of area
Before installing the equipment, the user shall make an 
assessment of potential electromagnetic problems in 
the surrounding area. The following shall be taken into 
account:
a.   Other supply cables, control cables, signaling and 
telephone cables; above, below and adjacent to the 
cutting equipment.
b.  Radio and television transmitters and receivers.
c.   Computer and other control equipment.
d.  Safety critical equipment, for example guarding 
ofindustrial equipment.
e.   Health of the people around, for example the use 
ofpacemakers and hearing aids.
f.   Equipment used for calibration or measurement.
g.  Immunity of other equipment in the environment. User 
shall ensure that other equipment being used in the 
environment is compatible. This may require additional 
protection measures.
h.   Time of day that cutting or other activities are to be 
carried out.
The size of the surrounding area to be considered 
will depend on the structure of the building and other 
activities that are taking place. The surrounding area may 
extend beyond the boundaries of the premises.
Methods of reducing emissions
Mains supply
Cutting equipment must be connected to the mains 
supply according to the manufacturer’s recommendations. 
If interference occurs, it may be necessary to take 
additional precautions such as filtering of the mains 
supply.