Table 18. POST conditions and results
Green LED Yellow LED State Action to be taken
Off Off Wake-up failure (dead
board)
Perform the AIX or IBM i operating system
diagnostics.
Off On POST failure (dead board) Perform the AIX or IBM i operating system
diagnostics.
Off Slow
flashing
Wake-up failure monitor Perform the AIX or IBM i operating system
diagnostics.
Off Fast flashes POST failure Perform the AIX or IBM i operating system
diagnostics.
Off Flashing POST processing in
progress
None
On Off Failure while functioning Perform the AIX or IBM i operating system
diagnostics.
On On Failure while functioning Perform the AIX or IBM i operating system
diagnostics.
Slow
flashes
Slow
flashing
Offline for download None
Slow
flashes
Fast flashes Restricted offline mode,
waiting for restart
None
Slow
flashes
Flashing Restricted offline mode,
test active
None
Replacing Fibre Channel adapters using hot swap
When hot swapping Fibre Channel adapters, be aware that device-related software for the storage
devices might have additional devices (for example, the dar device associated with the FAStT or DS4800)
that need to be removed. Refer to specic storage device documentation for information about how to
remove these additional devices.
The adapter has a unique worldwide port name (WWPN). Check the zoning and LUN assignments to
ensure that the new adapter functions as expected.
Operating system or partition requirements
If you are installing a new feature, ensure that you have the software that is required to support the new
feature and that you determine whether any prerequisites must be met for this feature and attaching
devices. For information about operating system and partition requirements, see one of the following
topics:
• The latest version of enabling libraries and utilities can be downloaded from Fix Central (http://
www.ibm.com/support/xcentral/).
• Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home).
• IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/
ssic/interoperability.wss).
• The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded
from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/
set2/sas/f/lopdiags/home.html).
• For support details, see the Linux Alert website (http://www14.software.ibm.com/webapp/set2/sas/f/
lopdiags/info/LinuxAlerts.html).
70
Power Systems: Managing PCIe adapters