EasyManua.ls Logo

IBM Aptiva 2134 - Page 82

IBM Aptiva 2134
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 2-1 (Page 19 of 25). POST and Diagnostics and Utilities Index
for Symptoms, Messages, Error Codes, or Beeps
Symptoms, Messages, Error
Codes, or Beeps
Action/FRU
163 - Real-time clock error. Set date and time.
Run the Setup Utility; see “POST Error
Codes” on page 2-3.
CMOS clock/battery (if less than 2.8 V dc)
System Board
164 - Memory size error. “Memory” on page 2-38.
Check SIMM installation and parity settings.
Run the Setup Utility. See “POST Error
Codes” on page 2-3 and also “SIMM
Configurations—Type A-1” on page 5-25.
SIMMs
I/O channel memory
System Board
1XX errors not listed above. System Board
20X - Memory error “Memory” on page 2-38.
SIMMs
I/O channel memory
System Board
221 - Shadow RAM error. “Memory” on page 2-38.
SIMMs
I/O channel memory
System Board
225 - SIMM installed in wrong
socket.
Refer to “SIMM Configurations—Type A-1”
on page 5-25 for correct installation.
228 - External cache tag RAM
error.
Optional cache tag address module.
229 - External cache memory
test error
“Memory” on page 2-38.
Cache tag address module and RAM
System Board
262 - DRAM parity configuration
error.
“Memory” on page 2-38.
Run the Setup Utility; see “POST Error
Codes” on page 2-3.
SIMMs
System Board
2-28

Table of Contents

Related product manuals