15.32.12.4 Self-test execution status
15
The self-test routine in progress
7
The self-test routine completed with read element failure
6
The self-test routine completed with servo element failure
5
The self-test routine completed with electrical element failure
4
The self-test routine completed with unknown element failure
3
The device was unable to complete the self-test routine due to a fatal error or
unknown test error
2
The self-test routine interrupted by the host with a hard or soft reset
1
The self-test routine aborted by the host
0
The self-test routine completed without error or has not been run
Current Self-test execution status
4–7
Percent Self-test remaining.
An approximate percentage of the self-test routine remaining until completion; given in
ten percent increments. Valid values are 0 through 9
0–3
DefinitionBit
15.32.12.5 Total time in seconds to complete off-line data collection activity
This field tells the host how many seconds the device requires to complete the off-line data collection
activity.
15.32.12.6 Off-line data collection capability
Reserved (0)
5–7
1
Self-test routine is implemented
0
Self-test routine is not implemented
Self-test implemented bit
4
1
The device supports Off-line Read Scanning
0
The device does not support Off-line Read Scanning
Off-line Read Scanning implemented bit
3
1
The device aborts off-line data collection activity upon receipt of a new
command
0
The device suspends off-line data collection activity after an interrupting
command and resume it after some vendor specific event
Abort/restart off-line by host bit
2
1
S.M.A.R.T. Enable/disable Automatic Off-line subcommand is implemented
0
S.M.A.R.T. Enable/disable Automatic Off-line subcommand is not implemented
Enable/disable Automatic Off-line implemented bit
1
1
S.M.A.R.T. Execute Off-line Immediate subcommand is implemented
0
S.M.A.R.T. Execute Off-line Immediate subcommand is not implemented
Execute Off-line Immediate implemented bit
0
DefinitionBit
Deskstar 60 GXP Hard disk drive specification