15.34 Standby Immediate (E0h/94h)
see below
Status
1 1 1 0 0 0 0 0
Command
- - - - - - - -
Device/Head
1 - 1 D - - - -
Device/Head
- - - - - - - -
Cylinder High
- - - - - - - -
Cylinder High
- - - - - - - -
Cylinder Low
- - - - - - - -
Cylinder Low
- - - - - - - -
Sector Number
- - - - - - - -
Sector Number
- - - - - - - -
Sector Count
- - - - - - - -
Sector Count
see below
Error
- - - - - - - -
Feature
- - - - - - - -
Data
- - - - - - - -
Data
7 6 5 4 3 2 1 0
Register
7 6 5 4 3 2 1 0
Register
Command Block Input
Registers
Command Block Output
Registers
V–0–V0V000V00000
ERRIDXCORDRQDSCDFRDYBSYAMNT0NABT0IDN0UNCCRC
0123
4
56701234567
Status RegisterError Register
Figure 134. Standby Immediate Command (E0h/94h)
The Standby Immediate command causes the device to enter Standby mode immediately.
The device is spun down but the interface remains active. If the device is already spun down, the spin
down sequence is not executed.
During the Standby mode the device will respond to commands, but there is a delay while waiting for the
spindle to reach operating speed.
The Standby Immediate command will not affect the auto power down time-out parameter.
Deskstar 60 GXP Hard disk drive specification
177