15.7 Idle (E3h/97h)
see below
Status
1 1 1 0 0 0 1 1
Command
- - - - - - - -
Device/Head
1 - 1 D - - - -
Device/Head
- - - - - - - -
Cylinder High
- - - - - - - -
Cylinder High
- - - - - - - -
Cylinder Low
- - - - - - - -
Cylinder Low
- - - - - - - -
Sector Number
- - - - - - - -
Sector Number
- - - - - - - -
Sector Count
V V V V V V V V
Sector Count
see below
Error
- - - - - - - -
Feature
- - - - - - - -
Data
- - - - - - - -
Data
7 6 5 4 3 2 1 0
Register
7 6 5 4 3 2 1 0
Register
Command Block Input
Registers
Command Block Output
Registers
V–0–V0V000V00000
ERRIDXCORDRQDSCDFRDYBSYAMNT0NABT0IDN0UNCCRC
0123456701234567
Status RegisterError Register
Figure 85. Idle Command (E3h/97h)
The Idle command causes the device to enter Idle mode immediately and to set the auto power down
time-out parameter (standby timer). And the timer then starts counting down.
When the Idle mode is entered, the device is spun up to operating speed. If the device is already
spinning, the spin up sequence is not executed.
During Idle mode the device is spinning and ready to respond to host commands immediately.