15.33 Standby (E2h/96h)
see below
Status
1 1 1 0 0 0 1 0
Command
- - - - - - - -
Device/Head
1 - 1 D - - - -
Device/Head
- - - - - - - -
Cylinder High
- - - - - - - -
Cylinder High
- - - - - - - -
Cylinder Low
- - - - - - - -
Cylinder Low
- - - - - - - -
Sector Number
- - - - - - - -
Sector Number
- - - - - - - -
Sector Count
V V V V V V V V
Sector Count
see below
Error
- - - - - - - -
Feature
- - - - - - - -
Data
- - - - - - - -
Data
7 6 5 4 3 2 1 0
Register
7 6 5 4 3 2 1 0
Register
Command Block Input
Registers
Command Block Output
Registers
V–0–V0V000V00000
ERRIDXCORDRQDSCDFRDYBSYAMNT0NABT0IDN0UNCCRC
0123456701234567
Status RegisterError Register
Figure 133. Standby Command (E2h/96h)
The Standby command causes the device to enter the Standby Mode immediately and to set the auto
power down time-out parameter (standby timer).
When the Standby mode is entered, the drive is spun down but the interface remains active. If the drive is
already spun down, the spin down sequence is not executed.
During the Standby mode the drive will respond to commands but there is a delay while waiting for the
spindle to reach operating speed.
The automatic power down sequence is enabled and the timer starts counting down when the drive
returns to Idle mode.
Deskstar 60 GXP Hard disk drive specification
175