15.8 Idle Immediate (E1h/95h)
see below
Status
1 1 1 0 0 0 0 1
Command
- - - - - - - -
Device/Head
1 - 1 D - - - -
Device/Head
- - - - - - - -
Cylinder High
- - - - - - - -
Cylinder High
- - - - - - - -
Cylinder Low
- - - - - - - -
Cylinder Low
- - - - - - - -
Sector Number
- - - - - - - -
Sector Number
- - - - - - - -
Sector Count
- - - - - - - -
Sector Count
see below
Error
- - - - - - - -
Feature
- - - - - - - -
Data
- - - - - - - -
Data
7 6 5 4 3 2 1 0
Register
7 6 5 4 3 2 1 0
Register
Command Block Input
Registers
Command Block Output
Registers
V–0–V0V000V00000
ERRIDXCORDRQDSCDFRDYBSYAMNT0NABT0IDN0UNCCRC
0123456701234567
Status RegisterError Register
Figure 86. Idle Immediate Command (E1h/95h)
The Idle Immediate command causes the device to enter Idle mode.
The device is spun up to operating speed. If the device is already spinning, the spin up sequence is not
executed.
During Idle mode the device is spinning and ready to respond to host commands immediately.
The Idle Immediate command will not affect the auto power down time-out parameter.
Deskstar 60 GXP Hard disk drive specification