EasyManua.ls Logo

IBM RS/6000 Enterprise Server M80 - Page 125

IBM RS/6000 Enterprise Server M80
567 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step 1524-3
1. Turn off the power.
2. Reinstall CEC power supply 2 that was removed in “Step 1524-2” on page 106.
3. Reconnect the ac power cable (dc power cable in a dc-powered system) to the CEC power supply 2.
4. Turn on the power.
Is the error code 1011 1C0x displayed?
NO The symptom has changed.
This ends the procedure.
YES Replace CEC power supply 2, location: U1.1-V2.
This ends the procedure. Go to MAP 0410: Repair Checkout in the RS/6000 and Eserver
pSeries Diagnostic Information for Multiple Bus Systems.
Step 1524-4
1. Turn off the power.
2. Reinstall CEC power supply 2 that was removed in “Step 1524-2” on page 106.
3. Reconnect the ac power cable (dc power cable in a dc-powered system) to the CEC power supply 2.
4. Disconnect the ac cable (dc power cable in a dc-powered system) to CEC power supply 1.
5. Remove CEC power supply 1.
6. Turn on the power.
Is the error code 1011 1C0x displayed?
NO Replace CEC power supply 1, location: U1.1-V1.
This ends the procedure. Go to MAP 0410: Repair Checkout in the RS/6000 and Eserver
pSeries Diagnostic Information for Multiple Bus Systems.
YES Go to “Step 1524-5” on page 108.
Chapter 3. Maintenance Analysis Procedures 107

Table of Contents

Other manuals for IBM RS/6000 Enterprise Server M80

Related product manuals