Step 1524-5
1. Turn off the power.
2. Reinstall CEC power supply 2 that was removed in “Step 1524-4” on page 107.
3. Reconnect the ac power cable (dc power cable in a dc-powered system) to the CEC power supply 2.
4. Remove CEC fan 1. Disregard a CEC fan error code if it occurs during this step.
5. Turn on the power.
Is the error code 1011 1C0x displayed?
NO Replace CEC fan 1, location: U1.1-F1.This ends the procedure. Go to MAP 0410: Repair
Checkout in the RS/6000 and Eserver pSeries Diagnostic Information for Multiple Bus Systems.
YES Go to “Step 1524-6.”
Step 1524-6
1. Turn off the power.
2. Reinstall CEC fan 1 that was removed in “Step 1524-5.”
3. Remove CEC fan 2. Disregard a CEC fan error code if it occurs during this step.
4. Turn on the power.
Is the error code 1011 1C0x displayed?
NO Replace CEC fan 2, location: U1.1-F2.This ends the procedure. Go to MAP 0410: Repair
Checkout in the RS/6000 and Eserver pSeries Diagnostic Information for Multiple Bus Systems.
YES Replace the CEC backplane, location: U1.1-P1.This ends the procedure. Go to MAP 0410:
Repair Checkout in the RS/6000 and Eserver pSeries Diagnostic Information for Multiple Bus
Systems.
108 Service Guide

Table of Contents

Other manuals for IBM RS/6000 Enterprise Server M80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 Enterprise Server M80 and is the answer not in the manual?

IBM RS/6000 Enterprise Server M80 Specifications

General IconGeneral
BrandIBM
ModelRS/6000 Enterprise Server M80
CategoryServer
LanguageEnglish

Related product manuals