EasyManuals Logo

IBM RS/6000 Enterprise Server M80 User Manual

IBM RS/6000 Enterprise Server M80
567 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #127 background imageLoading...
Page #127 background image
Step 1524-7
1. Turn off the power.
2. Disconnect the ac power cables (dc power cables in a dc-powered system) from the CEC drawer.
3. Reinstall one of the cards that was removed in “Step 1524-1” on page 106, in the sequence listed:
a. CEC regulator at M01
b. CEC RIO adapter at M06
c. CEC memory riser 1 at M02
d. CEC memory riser 2 at M05 (if present)
e. CEC processor at M03
f. CEC processor at M04 (if present)
4. Reconnect the ac power cables (dc power cables in a dc-powered system) to the CEC drawer.
5. Turn on the power.
Is the error code 1011 1C0x displayed?
NO Go to “Step 1524-8.”
YES The last card you installed is defective. Replace the last card you installed.This ends the
procedure. Go to MAP 0410: Repair Checkout in the RS/6000 and Eserver pSeries Diagnostic
Information for Multiple Bus Systems.
Step 1524-8
Have all the cards that were removed in “Step 1524-7” been reinstalled?
NO Go to “Step 1524-7” and reinstall the next card in the list.
YES Replace the CEC backplane, location: U1.1-P1.
This ends the procedure. Go to MAP 0410: Repair Checkout in the RS/6000 and Eserver
pSeries Diagnostic Information for Multiple Bus Systems.
Chapter 3. Maintenance Analysis Procedures 109

Table of Contents

Other manuals for IBM RS/6000 Enterprise Server M80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 Enterprise Server M80 and is the answer not in the manual?

IBM RS/6000 Enterprise Server M80 Specifications

General IconGeneral
BrandIBM
ModelRS/6000 Enterprise Server M80
CategoryServer
LanguageEnglish

Related product manuals