Table 5. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1011 3102 I2C bus 2 fault Primary I/O backplane
Location: U0.1-P1
1011 3104 I2C bus 4 fault Primary I/O backplane
Location: U0.1-P1
1011 3105 I2C bus 5 fault 1. Fan controller card
Location: U0.1-X2
2. Primary I/O backplane
Location: U0.1-P1
3. I/O drawer power distribution board
Location: U0.1-X1
1011 3113 RIO bus adapter fault Primary I/O drawer RIO bus adapter
Location: U0.1-P1.1
1011 3114 PCI backplane fault Primary I/O PCI backplane
Location: U0.1-P1
1011 3115 Primary drawer operator panel fault Primary I/O drawer operator panel
Location: U0.1-L1
1011 3116 Fan controller fault 1. Fan controller card
Location: U0.1-X2
2. Primary I/O backplane
Location: U0.1-P1
3. I/O drawer power distribution board
Location: U0.1-X1
1011 3117 System power/cooling control fault I/O backplane
Location: U0.1-P1
1011 3118 System power control network fault I/O backplane
Location: U0.1-P1
1011 311C Thermal sensor fault 1. Primary I/O drawer operator panel
Location: U0.1-L1
2. I/O backplane
Location: U0.1-P1
1011 7610 Slow I/O drawer fan 1 1. Fan 1
Location: U0.1-F1
2. Primary fan controller
Location: U0.1-X2
3. I/O drawer power distribution board
Location: U0.1-X1
1011 7611 Missing I/O drawer fan 1 Fan 1
Location: U0.1-F1
1011 7620 Slow I/O drawer fan 2 1. Fan 2
Location: U0.1-F2
2. Primary fan controller
Location: U0.1-X2
3. I/O drawer power distribution board
Location: U0.1-X1
1011 7621 Missing I/O drawer fan 2 Fan 2
Location: U0.1-F2