Table 5. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1031 3114 PCI backplane fault Secondary I/O backplane
Location: U0.3-P1
1031 3115 Operator panel fault Secondary I/O drawer operator panel
Location: U0.3-L1
1031 3116 Fan controller fault 1. Fan controller card
Location: U0.3-X2
2. Secondary I/O backplane
Location: U0.3-P1
3. I/O drawer power distribution board
Location: U0.3-X1
1031 3118 System power control network fault Secondary I/O backplane
Location: U0.3-P1
1031 311C Thermal sensor fault 1. Secondary I/O drawer operator panel
Location: U0.3-L1
2. Secondary I/O backplane
Location: U0.3-P1
1031 7610 Slow I/O drawer fan 1 1. Fan 1
Locaton: U0.3-F1
2. Fan controller card
Locaton: U0.3-X2
3. I/O drawer power distribution board
Location: U0.3-X1
1031 7611 Missing I/O drawer fan 1 Fan 1
Location: U0.3-F1
1031 7620 Slow I/O drawer fan 2 1. Fan 2
Locaton: U0.3-F2
2. Fan controller card
Locaton: U0.3-X2
3. I/O drawer power distribution board
Location: U0.3-X1
1031 7621 Missing I/O drawer fan 2 Fan 2
Location: U0.3-F2
1031 7630 Slow I/O drawer fan 3 1. Fan 3
Locaton: U0.3-F3
2. Fan controller card
Locaton: U0.3-X2
3. I/O drawer power distribution board
Location: U0.3-X1
1031 7631 Missing I/O drawer fan 3 Fan 3
Location: U0.3-F3
1031 7640 Slow I/O drawer fan 4 1. Fan 4
Locaton: U0.3-F4
2. Fan controller card
Locaton: U0.3-X2
3. I/O drawer power distribution board
Location: U0.3-X1
1031 7641 Missing I/O drawer fan 4 Fan 4
Location: U0.3-F4
184 Service Guide