Table 5. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1031 840F I/O type not recognized 1. Check cabling
2. From the main service processor menu,
select the System Information Menu,
then select the Power Control Network
Utilities Menu. Use option three to set
the I/O type to 84. Reboot the system.
3. Primary I/O drawer backplane
Location: U0.1-P1
1031 8A00 A different I/O drawer is connected to the
CEC
Informational only
1031 9012 Invalid address 1. Check SPCN cabling
2. Secondary I/O backplane
Location: U0.3-P1
1031 9013 Invalid address 1. Check SPCN cabling
2. Secondary I/O backplane
Location: U0.3-P1
1031 9014 Invalid address mode Update system firmware
Location: U0.1-P1/Y1
Note: Allow up to 30 minutes for this update
to take effect.
1031 9021 SPCN temporary internal error Information only
1031 9022 Secondary I/O drawer not present Check cabling
1031 9023 Secondary I/O drawer is present but off Information only
1031 902D Secondary I/O drawer not present Information only
1031 9038 I/O drawer node fault Secondary I/O backplane
Location: U0.3-P1
1031 9039 I/O drawer node fault Secondary I/O backplane
Location: U0.3-P1
1031 9042 EEPROM failure Secondary I/O backplane
Location: U0.3-P1
1031 9043 Download failure 1. Check for system firmware update
2. Call second level of support
1031 9046 QDS packet sequence error 1. Check for system firmware update
2. Call second level of support
1031 9047 QDS block sequence error 1. Check for system firmware update
2. Call second level of support
1031 9080 Undefined status code received Secondary I/O backplane
Location: U0.3-P1
1031 90F0 Drawer not present in configuration table 1. Check SPCN cabling
2. Reset system and reboot
3. Secondary I/O backplane
Location: U0.3-P1
1031 90F1 Drawer added to configuration table Information only
1031 9102 Permanent address assignment failed Secondary I/O backplane
Location: U0.3-P1
1031 9109 Download failure Secondary I/O backplane
Location: U0.3-P1
186 Service Guide