Table 5. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1031 9113 Firmware image corrupted Secondary I/O backplane
Location: U0.3-P1
1031 9114 Firmware image corrupted Secondary I/O backplane
Location: U0.3-P1
1031 9116 SPCN communication with operator panel
failure
1. Secondary I/O drawer operator panel
Location: U0.3-L1
2. Secondary I/O backplane
Location: U0.3-P1
1031 C62E Polling error 1. Check cabling
2. Secondary I/O backplane
Location: U0.3-P1
3. Primary I/O backplane
Location: U0.1-P1
1041 00AA System power control network firmware
update started (no error)
Information message
1041 1510 Power supply 1 power source failure 1. Check input to power supply 1
Location: U.4-V1
2. I/O drawer power supply 1
Locaton: U0.4-V1
3. Secondary I/O backplane
Locaton: U0.4-P1
1041 1511 Power supply 1 fault 1. I/O drawer power supply 1
Locaton: U0.4-V1
2. Secondary I/O backplane
Locaton: U0.4-P1
1041 1512 Power supply 1 non-power fault 1. I/O drawer power supply 1
Locaton: U0.4-V1
2. Secondary I/O backplane
Locaton: U0.4-P1
1041 1513 Power supply 1 domain fault 1. I/O drawer power supply 1
Locaton: U0.4-V1
2. Secondary I/O backplane
Locaton: U0.4-P1
1041 1514 Power supply 1 cooling fault 1. I/O drawer power supply 1
Locaton: U0.4-V1
2. Secondary I/O backplane
Locaton: U0.4-P1
1041 1516 Swapped power supply and cooling unit or
power supply 1 missing
1. Verify correct installation of power supply
and cooling unit
Location: U0.4-V1
2. Primary I/O power supply 1
Location: U0.4-V1
1041 1520 Power supply 2 power source failure 1. Check input power to power supply 2
Location: U0.4-V2
2. Secondary I/O drawer power supply 2
Location: U0.4-V2
3. Secondary I/O backplane
Location: U0.4-P1
Chapter 5. Error Code to FRU Index 187