Table 5. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1041 1B05 Load fault on 1.8 1. I/O drawer power supply
Location: U0.4-V1
2. If power supply U0.4-V2 is present (no
cooling unit), use the power supply you
removed from U0.4-V1 to replace
U0.4-V2
3. Secondary I/O backplane
Location: U0.4-P1
1041 1B06 Load fault on 2.5 1. I/O drawer power supply
Location: U0.4-V1
2. If power supply U0.4-V2 is present (no
cooling unit), use the power supply you
removed from U0.4-V1 to replace
U0.4-V2
3. Secondary I/O backplane
Location: U0.4-P1
1041 1B07 Load fault on 2.5 1. I/O drawer power supply
Location: U0.4-V1
2. If power supply U0.4-V2 is present (no
cooling unit), use the power supply you
removed from U0.4-V1 to replace
U0.4-V2
3. Secondary I/O backplane
Location: U0.4-P1
1041 2600 Pgood fault Secondary I/O backplane
Location: U0.4-P1
1041 2601 Pgood fault Secondary I/O backplane
Location: U0.4-P1
1041 2603 Secondary I/O drawer power domain fault 1. Check input power to power supplies
Locations: U0.4-V1
U0.4-V2
2. I/O drawer power supplies
Locations: U0.4-V1
U0.4-V2
3. I/O Drawer Power Distribution Board
Location: U0.4-X1
4. Secondary I/O backplane
Location: U0.4-P1
1041 2612 SPCN problem Secondary I/O backplane
Location: U0.4-P1
1041 3100 I2C controller fault Secondary I/O backplane
Location: U0.4-P1
1041 3101 I2C bus 1 fault 1. Secondary I/O drawer operator panel
Location: U0.4-L1
2. Secondary I/O backplane
Location: U0.4-P1
1041 3102 I2C bus 2 fault Secondary I/O backplane
Location: U0.4-P1
1041 3104 I2C bus 4 fault Secondary I/O backplane
Location: U0.4-P1
Chapter 5. Error Code to FRU Index 189