Table 5. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1041 3105 I2C bus 5 fault 1. Fan controller card
Location: U0.4-X2
2. Secondary I/O backplane
Location: U0.4-P1
3. I/O drawer power distribution board
Location: U0.4-X1
1041 3113 RIO bus adapter fault RIO bus adapter
Location: U0.4-P1.1
1041 3114 PCI backplane fault Secondary I/O backplane
Location: U0.4-P1
1041 3115 Operator panel fault Secondary I/O drawer operator panel
Location: U0.4-L1
1041 3116 Fan controller fault 1. Fan controller
Location: U0.4-X2
2. Secondary I/O backplane
Location: U0.4-P1
3. I/O drawer power distribution board
Location: U0.4-X1
1041 3118 System power control network fault Secondary I/O backplane
Location: U0.4-P1
1041 311C Thermal sensor fault 1. Secondary I/O operator panel
Location: U0.4-L1
2. Secondary I/O backplane
Location: U0.4-P1
1041 7610 Slow I/O drawer fan 1 1. Fan 1
Locaton: U0.4-F1
2. Fan controller card
Locaton: U0.4-X2
3. I/O drawer power distribution board
Location: U0.4-X1
1041 7611 Missing I/O drawer fan 1 Fan 1
Location: U0.4-F1
1041 7620 Slow I/O drawer fan 2 1. Fan 2
Locaton: U0.4-F2
2. Fan controller card
Locaton: U0.4-X2
3. I/O drawer power distribution board
Location: U0.4-X1
1041 7621 Missing I/O drawer fan 2 Fan 2
Location: U0.4-F2
1041 7630 Slow I/O drawer fan 3 1. Fan 3
Locaton: U0.4-F3
2. Fan controller card
Locaton: U0.4-X2
3. I/O drawer power distribution board
Location: U0.4-X1
1041 7631 Missing I/O drawer fan 3 Fan 3
Location: U0.4-F3