Table 5. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1041 7640 Slow I/O drawer fan 4 1. Fan 4
Locaton: U0.4-F4
2. Fan controller card
Locaton: U0.4-X2
3. I/O drawer power distribution board
Location: U0.4-X1
1041 7641 Missing I/O drawer fan 4 Fan 4
Location: U0.4-F4
1041 7650 Slow I/O drawer fan 5 in power supply 1 1. Fan 5 I/O drawer power supply 1
Locaton: U0.4-V1
2. Fan controller card
Locaton: U0.4-X2
3. I/O drawer power distribution board
Location: U0.4-X1
1041 7651 Missing I/O drawer fan 5 in power supply 1 I/O drawer power supply 1
Location: U0.4-V1
1041 7660 Slow I/O drawer fan 6 in I/O drawer power
supply 2
1. I/O drawer power supply 2
Locaton: U0.4-V2
2. Fan controller card
Locaton: U0.4-X2
3. I/O drawer power distribution board
Location: U0.4-X1
1041 7661 Missing I/O drawer fan 6 in I/O drawer power
supply 2
I/O drawer power supply 2
Location: U0.4-V2
1041 7690 Slow I/O drawer fan 9 in cooling unit 1. Fan 9 (cooling unit)
Locaton: U0.4-F9
2. Fan controller card
Locaton: U0.4-X2
3. I/O drawer power distribution board
Location: U0.4-X1
1041 7691 Missing I/O drawer fan 9 in cooling unit Fan 9 (cooling unit)
Location: U0.4-F9
1041 8400 VPD configuration problem 1. Check for system firmware update
2. Call second level of support
1041 8401 VPD access problem 1. Check for system firmware update
2. Call second level of support
1041 840A VPD +5 stuck high Secondary I/O backplane
Location: U0.4-P1
1041 840B VPD +5 stuck low Secondary I/O backplane
Location: U0.4-P1
1041 840D I/O type mismatch 1. Check cabling
2. From the main service processor menu,
select the System Information Menu,
then select the Power Control Network
Utilities Menu. Use option three to set
the I/O type to 84. Reboot the system.
3. Primary I/O drawer backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index 191