EasyManuals Logo

IBM RS/6000 Enterprise Server M80 User Manual

IBM RS/6000 Enterprise Server M80
567 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #210 background imageLoading...
Page #210 background image
Table 5. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1041 840E SPCN default configuration loaded 1. Check cabling
2. From the main service processor menu,
select the System Information Menu,
then select the Power Control Network
Utilities Menu. Use option three to set
the I/O type to 84. Reboot the system.
3. Primary I/O drawer backplane
Location: U0.1-P1
1041 840F I/O type not recognized 1. Check cabling
2. From the main service processor menu,
select the System Information Menu,
then select the Power Control Network
Utilities Menu. Use option three to set
the I/O type to 84. Reboot the system.
3. Primary I/O drawer backplane
Location: U0.1-P1
1041 8A00 A different I/O drawer is connected to the
CEC
Informational only
1041 9012 Invalid address 1. Check SPCN cabling
2. Secondary I/O Backplane
Location: U0.2-P1
1041 9013 Invalid address 1. Check SPCN cabling
2. Secondary I/O Backplane
Location: U0.2-P1
1041 9014 Invalid address mode Update system firmware
Location: U0.1-P1/Y1
Note: Allow up to 30 minutes for this update
to take effect.
1041 9021 SPCN temporary internal error Information only
1041 9022 Secondary I/O drawer not present Check cabling
1041 9023 Secondary I/O drawer is present but off Information only
1041 902D Secondary I/O drawer not present Information only
1041 9038 I/O drawer node fault Secondary I/O backplane
Location: U0.4-P1
1041 9039 I/O drawer node fault Secondary I/O backplane
Location: U0.4-P1
1041 9042 EEPROM failure Secondary I/O backplane
Location: U0.4-P1
1041 9043 Download failure 1. Check for system firmware update
2. Call second level of support
1041 9046 QDS packet sequence error 1. Check for system firmware update
2. Call second level of support
1041 9047 QDS block sequence error 1. Check for system firmware update
2. Call second level of support
1041 9080 Undefined status code received Secondary I/O backplane
Location: U0.4-P1
192 Service Guide

Table of Contents

Other manuals for IBM RS/6000 Enterprise Server M80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 Enterprise Server M80 and is the answer not in the manual?

IBM RS/6000 Enterprise Server M80 Specifications

General IconGeneral
BrandIBM
ModelRS/6000 Enterprise Server M80
CategoryServer
LanguageEnglish

Related product manuals