Table 5. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1041 90F0 Drawer not present in configuration table 1. Check SPCN cabling
2. Reset system and reboot
3. Secondary I/O backplane
Location: U0.2-P1
1041 90F1 Drawer added to configuration table Information only
1041 9102 Permanent address assignment failed Secondary I/O backplane
Location: U0.4-P1
1041 9109 Download failure Secondary I/O backplane
Location: U0.4-P1
1041 9113 Firmware image corrupted Secondary I/O backplane
Location: U0.4-P1
1041 9114 Firmware image corrupted Secondary I/O backplane
Location: U0.4-P1
1041 9116 SPCN communication with operator panel
failure
1. Secondary I/O drawer operator panel
Location: U0.4-P1
2. Secondary I/O Backplane
Location: U0.4-P1
1041 C62E Polling error 1. Check cabling
2. Secondary I/O backplane
Location: U0.4-P1
3. Primary I/O backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index 193