Table 6. Firmware Error Codes. (continued)
Error Code Description Action/
Possible Failing FRU
25Cy y002 Memory DIMM failure
Refer to “Memory Riser Card and Memory
DIMM Locations” on page 19 to determine
the octal DIMMs.
See “System Information Menu” on page 372
for more information on the error status of
memory DIMMs.
If one memory DIMM is called out:
1. Replace the memory DIMM.
2. Replace the entire octal that contains the
memory DIMM.
3. Replace the memory riser card.
If
more than one memory DIMM is called out,
go to the ″Memory
Configuration/Deconfiguration menu″, which
is under the ″System Information Menu″ on
the main service processor menu:
1. From the memory
configuration/deconfiguration menu, select
the card(s) specified by the location
code(s) of the failing memory DIMM(s). If
the first character of the error status of
any memory DIMM is 1, 2, or 3 (but not 0
or 4), this is a suspect memory DIMM.
Record its location.
2. If only one DIMM was recorded in step
one:
a. Replace DIMM
b. Replace the entire octal that contains
the memory DIMM.
c. Replace the memory riser card
3.
If more than one DIMM was recorded in
step one and the DIMMs reside in more
than one octal:
a. Replace the memory riser card
b. Replace all failing DIMMs
4.
If more than 1 DIMM was recorded in
step one and they reside in one octal:
a. Replace all failing DIMMs
b. Replace the memory riser card
2602 0001 Invalid PCI adapter vendor ID 1. Move adapter to another slot.
2. Check for available firmware updates for
adapter. Apply update if available.
3. Run AIX diagnostics on adapter. Replace
if indicated.
4. Replace adapter.
5. Check for system firmware updates.
Apply if update available.
6. Replace I/O drawer backplane (See notes
on Chapter 5, “Error Code to FRU Index,”
on page 159.)
2602 0002 Invalid PCI adapter device ID 1. Move adapter to another slot.
2. Check for available firmware updates for
adapter. Apply update if available.
3. Run AIX diagnostics on adapter. Replace
if indicated.
4. Replace adapter.
5. Check for system firmware updates.
Apply if update available.
6. Replace I/O drawer backplane. (See
notes on Chapter 5, “Error Code to FRU
Index,” on page 159.)
Chapter 5. Error Code to FRU Index 205