Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4069 0525 Memory test detected memory DIMM fault Memory DIMM 21, riser 2
Location: U1.1-P1-M2.21
4069 0526 Memory test detected memory DIMM fault Memory DIMM 22, riser 2
Location: U1.1-P1-M2.22
4069 0527 Memory test detected memory DIMM fault Memory DIMM 29, riser 2
Location: U1.1-P1-M2.29
4069 0528 Memory test detected memory DIMM fault Memory DIMM 30, riser 2
Location: U1.1-P1-M2.30
4069 052D Memory test detected memory DIMM group
fault
Memory octal C, riser 2
Location: U1.1-P1-M2.5 x8
4069 052E Memory test detected memory DIMM group
pair A fault
Memory quad C odd, riser 2
Location: U1.1-P1-M2.5 x4
4069 052F Memory test detected memory DIMM group
fault
Memory quad C even, riser 2
Location: U1.1-P1-M2.6 x4
4069 0531 Memory test detected memory DIMM fault Memory DIMM 7, riser 2
Location: U1.1-P1-M2.7
4069 0532 Memory test detected memory DIMM fault Memory DIMM 8, riser 2
Location: U1.1-P1-M2.8
4069 0533 Memory test detected memory DIMM fault Memory DIMM 15, riser 2
Location: U1.1-P1-M2.15
4069 0534 Memory test detected memory DIMM fault Memory DIMM 16, riser 2
Location: U1.1-P1-M2.16
4069 0535 Memory test detected memory DIMM fault Memory DIMM 23, riser 2
Location: U1.1-P1-M2.23
4069 0536 Memory test detected memory DIMM fault Memory DIMM 24, riser 2
Location: U1.1-P1-M2.24
4069 0537 Memory test detected memory DIMM fault Memory DIMM 31, riser 2
Location: U1.1-P1-M2.31
4069 0538 Memory test detected memory DIMM fault Memory DIMM 32, riser 2
Location: U1.1-P1-M2.32
4069 053D Memory test detected memory DIMM group
fault
Memory octal D, riser 2
Location: U1.1-P1-M2.7 x8
4069 053E Memory test detected memory DIMM group
fault
Memory quad D odd, riser 2
Location: U1.1-P1-M2.7 x4
4069 053F Memory test detected memory DIMM group
fault
Memory quad D even, riser 2
Location: U1.1-P1-M2.8 x4
4069 05FF Memory test detected memory on riser fault Memory failure on riser card 2 that cannot be
automatically isolated. go to “MAP 1540:
Minimum Configuration” on page 110 and run
CEC drawer minimum configuration for
further isolation.
4069 0600 Memory test detected CEC RIO bus adapter CEC RIO bus adapter
Location: U1.1-P1.1
4069 0601 Memory test detected clock card fault CEC clock card
Location: U1.1-P1.1.1
4069 3101 Memory test detected RIO port 0 fault CEC RIO bus adapter
Location: U1.1-P1.1
Chapter 5. Error Code to FRU Index 233