Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4069 0504 Memory test detected memory DIMM fault Memory DIMM 10, riser 2
Location: U1.1-P1-M2.10
4069 0505 Memory test detected memory DIMM fault Memory DIMM 17, riser 2
Location: U1.1-P1-M2.17
4069 0506 Memory test detected memory DIMM fault Memory DIMM 18, riser 2
Location: U1.1-P1-M2.18
4069 0507 Memory test detected memory DIMM fault Memory DIMM 25, riser 2
Location: U1.1-P1-M2.25
4069 0508 Memory test detected memory DIMM fault Memory DIMM 26, riser 2
Location: U1.1-P1-M2.26
4069 050D Memory test detected memory DIMM group
fault
Memory octal A, riser 2
Location: U1.1-P1-M2.1 x8
4069 050E Memory test detected memory DIMM group
pair A fault
Memory quad A odd, riser 2
Location: U1.1-P1-M2.1 x4
4069 050F Memory test detected memory DIMM group
fault
Memory quad A even, riser 2
Location: U1.1-P1-M2.2 x4
4069 0511 Memory test detected memory DIMM fault Memory DIMM 3, riser 2
Location: U1.1-P1-M2.3
4069 0512 Memory test detected memory DIMM fault Memory DIMM 4, riser 2
Location: U1.1-P1-M2.4
4069 0513 Memory test detected memory DIMM fault Memory DIMM 11, riser 2
Location: U1.1-P1-M2.11
4069 0514 Memory test detected memory DIMM fault Memory DIMM 12, riser 2
Location: U1.1-P1-M2.12
4069 0515 Memory test detected memory DIMM fault Memory DIMM 19, riser 2
Location: U1.1-P1-M2.19
4069 0516 Memory test detected memory DIMM fault Memory DIMM 20, riser 2
Location: U1.1-P1-M2.20
4069 0517 Memory test detected memory DIMM fault Memory DIMM 27, riser 2
Location: U1.1-P1-M2.27
4069 0518 Memory test detected memory DIMM fault Memory DIMM 28, riser 2
Location: U1.1-P1-M2.28
4069 051D Memory test detected memory DIMM group
fault
Memory octal B, riser 2
Location: U1.1-P1-M2.3 x8
4069 051E Memory test detected memory DIMM group
fault
Memory quad B odd, riser 2
Location: U1.1-P1-M2.3 x4
4069 051F Memory test detected memory DIMM group
fault
Memory quad B even, riser 2
Location: U1.1-P1-M2.4 x4
4069 0521 Memory test detected memory DIMM fault Memory DIMM 5, riser 2
Location: U1.1-P1-M2.5
4069 0522 Memory test detected memory DIMM fault Memory DIMM 6, riser 2
Location: U1.1-P1-M2.6
4069 0523 Memory test detected memory DIMM fault Memory DIMM 13, riser 2
Location: U1.1-P1-M2.13
4069 0524 Memory test detected memory DIMM fault Memory DIMM 14, riser 2
Location: U1.1-P1-M2.14
232 Service Guide