Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4069 3285 Memory test detected PCI controller PHB1 1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
4069 3286 Memory test detected PCI controller PHB2 1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
406A 0001 Self test detected CEC backplane failure CEC backplane
Location: U1.1-P1
406A 0003 Self test detected processor fault All processors
Location: U1.1-P1-C1
406A 0009 Self test detected memory fault All memory
Location: U1.1-P1-M1 x2
406A 00A0 Self test detected CSP service processor
firmware fault
Update system firmware
Location: U0.1-P1/Y1
406A 00A1 Self test detected AIX or system firmware
fault
1. Check for AIX updates
2. Check for system firmware updates
Location: U0.1-P1/Y1
406A 00A2 Self test detected service processor firmware
(processor runtime diagnostics) fault
Check for system firmware updates
Location: U0.1-P1/Y1
406A 00A3 Self test detected memory plugging fault All pluggable memory
406A 00A4 Self test detected application caused fault Application software
406A 00A5 Self test detected invalid system configuration Verify system components are supported and
properly installed.
406A 00A6 Self test detected no usable memory 1. Ensure that CEC memory is properly
installed.
2. If more than one DIMM is called out, go
to the service processor Memory
Configuration/Deconfiguration Menu to
verify memory DIMMs state. See
Memory Configuration/Deconfiguration
Menu on page 374 for more information.
406A 00A7 Self test detected hardware problem Go to minimum configuration and also run
CEC minimum configuration
406A 00B0 Self test detected bus controller lock-unlock
failure
RIO bus adapter
Location: U0.1-P1.1
406A 00B1 Self test detected bus controller failure RIO bus adapter
Location: U0.1-P1.1
406A 00B3 Self test detected clock fault 1. Clock card
Location: U1.1-P1.1.1
2. CEC RIO bus adapter
Location: U1.1-P1.1
Chapter 5. Error Code to FRU Index 235