Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
406A 00B7 Self test detected insufficient hardware
resources to continue IPL
This error code appears after the initial
testing by the service processor firmware on
the CEC was completed correctly, but a
problem occurred when the firmware tried to
communicate outside the CEC. Suspect a
problem with the RIO interface, either cables
or adapters.
406A 0200 Self test detected memory riser card fault Memory riser card 1
Location: U1.1-P1-M1
406A 0201 Self test detected memory DIMM fault Memory DIMM 1, riser 1
Location: U1.1-P1-M1.1
406A 0202 Self test detected memory DIMM fault Memory DIMM 2, riser 1
Location: U1.1-P1-M1.2
406A 0203 Self test detected memory DIMM fault Memory DIMM 9, riser 1
Location: U1.1-P1-M1.9
406A 0204 Self test detected memory DIMM fault Memory DIMM 10, riser 1
Location: U1.1-P1-M1.10
406A 0205 Self test detected memory DIMM fault Memory DIMM 17, riser 1
Location: U1.1-P1-M1.17
406A 0206 Self test detected memory DIMM fault Memory DIMM 18, riser 1
Location: U1.1-P1-M1.18
406A 0207 Self test detected memory DIMM fault Memory DIMM 25, riser 1
Location: U1.1-P1-M1.25
406A 0208 Self test detected memory DIMM fault Memory DIMM 26, riser 1
Location: U1.1-P1-M1.26
406A 020D Self test detected memory DIMM group fault Memory octal A, riser 1
Location: U1.1-P1-M1.1 x8
406A 020E Self test detected memory DIMM group fault Memory quad A odd, riser 1
Locations: U1.1-P1-M1.1 x4
406A 020F Self test detected memory DIMM group fault Memory quad A even, riser 1
Locations: U1.1-P1-M1.2 x4
406A 0211 Self test detected memory DIMM fault Memory DIMM 3, riser 1
Location: U1.1-P1-M1.3
406A 0212 Self test detected memory DIMM fault Memory DIMM 4, riser 1
Location: U1.1-P1-M1.4
406A 0213 Self test detected memory DIMM fault Memory DIMM 11, riser 1
Location: U1.1-P1-M1.11
406A 0214 Self test detected memory DIMM fault Memory DIMM 12, riser 1
Location: U1.1-P1-M1.12
406A 0215 Self test detected memory DIMM fault Memory DIMM 19, riser 1
Location: U1.1-P1-M1.19
406A 0216 Self test detected memory DIMM fault Memory DIMM 20, riser 1
Location: U1.1-P1-M1.20
406A 0217 Self test detected memory DIMM fault Memory DIMM 27, riser 1
Location: U1.1-P1-M1.27
406A 0218 Self test detected memory DIMM fault Memory DIMM 28, riser 1
Location: U1.1-P1-M1.28
236 Service Guide