Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
406A 021D Self test detected memory DIMM group fault Memory octal B, riser 1
Location: U1.1-P1-M1.3 x8
406A 021E Self test detected memory DIMM group pair
A fault
Memory quad B odd, riser 1
Location: U1.1-P1-M1.3 x4
406A 021F Self test detected memory DIMM group fault Memory quad B even, riser 1
Location: U1.1-P1-M1.4 x4
406A 0221 Self test detected memory DIMM fault Memory DIMM 5, riser 1
Location: U1.1-P1-M1.5
406A 0222 Self test detected memory DIMM fault Memory DIMM 6, riser 1
Location: U1.1-P1-M1.6
406A 0223 Self test detected memory DIMM fault Memory DIMM 13, riser 1
Location: U1.1-P1-M1.13
406A 0224 Self test detected memory DIMM fault Memory DIMM 14, riser 1
Location: U1.1-P1-M1.14
406A 0225 Self test detected memory DIMM fault Memory DIMM 21, riser 1
Location: U1.1-P1-M1.21
406A 0226 Self test detected memory DIMM fault Memory DIMM 22, riser 1
Location: U1.1-P1-M1.22
406A 0227 Self test detected memory DIMM fault Memory DIMM 29, riser 1
Location: U1.1-P1-M1.29
406A 0228 Self test detected memory DIMM fault Memory DIMM 30, riser 1
Location: U1.1-P1-M1.30
406A 022D Self test detected memory DIMM group fault Memory octal C, riser 1
Locations: U1.1-P1-M1.5 x8
406A 022E Self test detected memory DIMM group pair
A fault
Memory quad C odd, riser 1
Locations: U1.1-P1-M1.5 x4
406A 022F Self test detected memory DIMM group fault Memory quad C even, riser 1
Locations: U1.1-P1-M1.6 x4
406A 0231 Self test detected memory DIMM fault Memory DIMM 7, riser 1
Location: U1.1-P1-M1.7
406A 0232 Self test detected memory DIMM fault Memory DIMM 8, riser 1
Location: U1.1-P1-M1.8
406A 0233 Self test detected memory DIMM fault Memory DIMM 15, riser 1
Location: U1.1-P1-M1.15
406A 0234 Self test detected memory DIMM fault Memory DIMM 16, riser 1
Location: U1.1-P1-M1.16
406A 0235 Self test detected memory DIMM fault Memory DIMM 23, riser 1
Location: U1.1-P1-M1.23
406A 0236 Self test detected memory DIMM fault Memory DIMM 24, riser 1
Location: U1.1-P1-M1.24
406A 0237 Self test detected memory DIMM fault Memory DIMM 31, riser 1
Location: U1.1-P1-M1.31
406A 0238 Self test detected memory DIMM fault Memory DIMM 32, riser 1
Location: U1.1-P1-M1.32
406A 023D Self test detected memory DIMM group fault Memory octal D, riser 1
Location: U1.1-P1-M1.7 x8
Chapter 5. Error Code to FRU Index 237