Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
406A 023E Self test detected memory DIMM group fault Memory quad D odd, riser 1
Location: U1.1-P1-M1.7 x4
406A 023F Self test detected memory DIMM group fault Memory quad D even, riser 1
Location: U1.1-P1-M1.8 x4
406A 02FF Self test detected memory on riser fault All memory on riser 1
Location: U1.1-P1-M1.1 x32
Memory failure on riser card 1 that cannot be
automatically isolated. go to “MAP 1540:
Minimum Configuration” on page 110 and run
CEC drawer minimum configuration for
further isolation.
406A 0300 Self test detected processor card fault Processor card
Location: U1.1-P1-C1
406A 0400 Self test detected processor card fault Processor card
Location: U1.1-P1-C2
406A 0500 Self test detected memory riser card fault Memory riser card 2
Location: U1.1-P1-M1
406A 0501 Self test detected memory DIMM fault Memory DIMM 1, riser 2
Location: U1.1-P1-M2.1
406A 0502 Self test detected memory DIMM fault Memory DIMM 2, riser 2
Location: U1.1-P1-M2.2
406A 0503 Self test detected memory DIMM fault Memory DIMM 9, riser 2
Location: U1.1-P1-M2.9
406A 0504 Self test detected memory DIMM fault Memory DIMM 10, riser 2
Location: U1.1-P1-M2.10
406A 0505 Self test detected memory DIMM fault Memory DIMM 17, riser 2
Location: U1.1-P1-M2.17
406A 0506 Self test detected memory DIMM fault Memory DIMM 18, riser 2
Location: U1.1-P1-M2.18
406A 0507 Self test detected memory DIMM fault Memory DIMM 25, riser 2
Location: U1.1-P1-M2.25
406A 0508 Self test detected memory DIMM fault Memory DIMM 26, riser 2
Location: U1.1-P1-M2.26
406A 050D Self test detected memory DIMM group fault Memory octal A, riser 2
Location: U1.1-P1-M2.1 x8
406A 050E Self test detected memory DIMM group pair
A fault
Memory quad A odd, riser 2
Location: U1.1-P1-M2.1 x4
406A 050F Self test detected memory DIMM group fault Memory quad A even, riser 2
Location: U1.1-P1-M2.2 x4
406A 0511 Self test detected memory DIMM fault Memory DIMM 3, riser 2
Location: U1.1-P1-M2.3
406A 0512 Self test detected memory DIMM fault Memory DIMM 4, riser 2
Location: U1.1-P1-M2.4
406A 0513 Self test detected memory DIMM fault Memory DIMM 11, riser 2
Location: U1.1-P1-M2.11
406A 0514 Self test detected memory DIMM fault Memory DIMM 12, riser 2
Location: U1.1-P1-M2.12
238 Service Guide